Specifications - Power Plant 12
Environment Specification |
US/JP |
Europe/Asia |
Location | Indoor use only | Indoor use only |
Duty Cycle | Suitable for continuous operation | Suitable for continuous operation |
Moisture Sensitivity | Not sealed against moisture | Not sealed against moisture |
Operating Humidity | <80%rh | <80%rh |
Storage Temperature | -40C to +40C | -40C to +40C |
Operating Temperature | 0C to 40C | 0C to 40C |
Max Operating Altitude | 12,000’ (3500m) | 12,000’ (3500m) |
Electrical Supply Nominal Rating | 120V 15A 60Hz US 100V 15A 50/60 Hz JP |
230V 10A 50/60Hz |
Instrument Specification |
||
Unit Dimensions | 17” W x 14” D x 4” H (43cm W x 36cm D x 10.16 cm H) | 17” W x 14” D x 4” H (43cm W x 36cm D x 10.16 cm H) |
Unit Weight | 37 lbs ( 16.7kg) | 37 lbs ( 16.7kg) |
Shipping Dimensions | 24” x 21” x 10” ( 61cm x 53cm x 25cm) | 24” x 21” x 10” ( 61cm x 53cm x 25cm) |
Shipping Weight | 48 lbs (21.7kg) | 48 lbs (21.7kg) |
Nominal Input Voltage | 95 – 145 VAC | 200 –285VAC |
Maximum Continuous Load | 1000VA | 1200VA |
Maximum Peak Load | 3600VA | 3800VA |
Voltage Regulation | 0.5V | 1V |
Output Distortion (Resistive Load) | <0.5% | <0.9% |
Output Distortion (Reactive Load) | <0.5% 0.1% typical |
<0.9% 0.1% typical |
Output Impedance | <0.008 ohm | <0.008 ohm |
Noise Reduction | 100kHz – 2MHz >80dB | 100kHz – 2MHz >80dB |
Efficiency @1200 VA | >85% | >85% |
Input Frequency | 45 – 65 Hz | 45 – 65 Hz |
Under Voltage Limit | US - 90 V JP - 75 V |
174 V |
Over Voltage Limit | US - 144 V JP - 120 V |
275 V |
Energy Dissipation | 1020J | 1270J |
Peak Current Surge | 90,000A | 90,000A |
Max Surge Voltage | 6,000V | 6,000V |
Clamp Level | 340V | 800V |
DC Trigger Configuration | Tip Positive | Tip Positive |
DC Trigger Voltage | 5 – 15Vdc | 5 – 15Vdc |