Specifications - Power Plant 12

Environment Specification

US/JP

Europe/Asia

Location Indoor use only Indoor use only
Duty Cycle Suitable for continuous operation Suitable for continuous operation
Moisture Sensitivity Not sealed against moisture Not sealed against moisture
Operating Humidity <80%rh <80%rh
Storage Temperature -40C to +40C -40C to +40C
Operating Temperature 0C to 40C 0C to 40C
Max Operating Altitude 12,000’ (3500m) 12,000’ (3500m)
Electrical Supply Nominal Rating 120V 15A 60Hz US
100V 15A 50/60 Hz JP
230V 10A 50/60Hz

Instrument Specification

Unit Dimensions 17” W x 14” D x 4” H (43cm W x 36cm D x 10.16 cm H) 17” W x 14” D x 4” H (43cm W x 36cm D x 10.16 cm H)
Unit Weight 37 lbs ( 16.7kg) 37 lbs ( 16.7kg)
Shipping Dimensions 24” x 21” x 10” ( 61cm x 53cm x 25cm) 24” x 21” x 10” ( 61cm x 53cm x 25cm)
Shipping Weight 48 lbs (21.7kg) 48 lbs (21.7kg)
Nominal Input Voltage 95 – 145 VAC 200 –285VAC
Maximum Continuous Load 1000VA 1200VA
Maximum Peak Load 3600VA 3800VA
Voltage Regulation 0.5V 1V
Output Distortion (Resistive Load) <0.5% <0.9%
Output Distortion (Reactive Load) <0.5%
0.1% typical
<0.9%
0.1% typical
Output Impedance <0.008 ohm <0.008 ohm
Noise Reduction 100kHz – 2MHz >80dB 100kHz – 2MHz >80dB
Efficiency @1200 VA >85% >85%
Input Frequency 45 – 65 Hz 45 – 65 Hz
Under Voltage Limit US - 90 V
JP - 75 V
174 V
Over Voltage Limit US - 144 V
JP - 120 V
275 V
Energy Dissipation 1020J 1270J
Peak Current Surge 90,000A 90,000A
Max Surge Voltage 6,000V 6,000V
Clamp Level 340V 800V
DC Trigger Configuration Tip Positive Tip Positive
DC Trigger Voltage 5 – 15Vdc 5 – 15Vdc